BRO_CHILL_2018 Printed in USA
Friedrich Air Conditioning Co. l 10001 Reunion Place, Suite 500 l San Antonio, TX 78216 l 877.599.5665 l www.friedrich.com
(B)
(C)
Front
SIDE VIEW
Sleeve Dimensions Drawing
Area to be
Conditioned
in sq. ft.
Approximate
Cooling
Btu Required
100 - 150 5000
150 - 250 6000
250 - 300 7000
300 - 350 8000
350 - 400 9000
400 - 450 10000
450 - 550 12000
550 - 700 14000
700 - 1000 18000
1000 - 1200 21000
1200 - 1400 23000
1400 - 1500 24000
COOLING
SIZING GUIDE
Based on normal room insulation, average
number of sun exposed windows and two
person occupancy.
1. If heavily shaded, reduce cooling Btus
required by 10%
2. If very sunny, increase cooling Btus
required by 10%
3. Add 500 Btus per person for more than
2 people
4. Add 4,000 Btus if the area is a kitchen
All Chill models have sleeve built into the unit.
* Minimum extensions when mounted in a window.
** Minimum widths achieved using one side curtain assembly as opposed to both in a standard installation.
† Sleeve P1 does not have In-wall hole dimensions, as these units are xed chassis and should not be installed In-wall.
INSTALLATION
Sleeve
Height
Inches
Width
Inches
Depth
with Front
Inches
Shell Depth
to Louvers
Inches
Minimum
Extension
Into Room*
Inches
Minimum
Extension
Outside
* Inches
Window Width
Inches
In-wall Installation
Finished Hole Inches
Carton Dimensions
Inches
Minimum** Maximum Height Width
Max. Depth
Height Width Depth
P1† 12
5
/16
”
18
9
/16
"
15
7
/16
5"
3
½"
10
¾"
20
1
/8
" 36" NOT FOR THRU-WALL 15
1
/
4
" 22
1
/
4
" 17
1
/
2
"
P6 13
7
/8
" 18
9
/16
" 20
11
/16
" 8
1
/8
"
4
½"
11" 20
1
/8
" 36" 14
1
/8
" 18
7
/8
" 7 ½" 17
7
/8
" 22
3
/
4
" 22"
P7 15" 23
5
/8
" 22
1
/16
”
8
¾"
4
½"
12" 25 ¼" 39" 15 ¼" 23
7
/8
" 8" 18
3
/
4
" 26
3
/
4
" 23
7
/
8
"
P9 16
7
/8
" 25
1
/2
” 30
5
/16
” 10
1
/4
"
5
½"
19
½"
26
½
"
42" 17
1
/8
" 26 ¼" 9" 21
1
/
2
" 33" 28
7
/
8
"
CP05G10B 125V - 15A 5 -15P 6 1/2
CP06G10B, CP08G10B,
CP10G10B, CP12G10B and
CP15G10B. EP08G11B.
125V - 15A 5- 15P 6
CP18G30B 250V - 15A 6 - 15P 4 1/2
CP24G30B.
EP12G33B, EP18G33B and
EP24G33B.
250V - 20A 6 - 20P 4
LISTED
ROOM AIR CONDITIONERS