Seite 1 - Service and Parts

Room Air ConditionerService and PartsManualCP10 CP12 SVC PARTS 2008 (07/08) CP10E10 CP12E100FPowerModeTimer0n/0ffFan SpeedTemp CoolMoney

Seite 2 - TABLE OF CONTENTS

DisassemblyDisassemblyMechanical Parts— Before the following disassembly, POWER SWITCH set to OFF and disconnect the power cord.1. FRONT GRILLE1. Open

Seite 3 - Safety Precautions

11 Room Air ConditionerDisassemblyAir Handling Parts—7—1. AIR GUIDE AND BLOWER1. Remove the front grille.2. Remove the cabinet. 3. Remove the control

Seite 4 - 4 Room Air Conditioner

Service Manual 12Electrical Parts1. Remove the cabinet. 2. Remove the evaporator. 3. Remove the orifice. 4. Remove the blower. 5. Remove the fan.6. Re

Seite 5 - Service Manual 5

Service Manual 13Disassembly7. POWER CORDRefrigerating CycleCAUTION: Discharge the refrigerant system using a FreonTMRecovery System. If there is no v

Seite 6 - Dimensions

14 Room Air ConditionerDisassembly— Replacement of the refrigeration cycle.1. When replacing the refrigeration cycle, be sure toDischarge the refriger

Seite 7 - Product Specifications

Service Manual 15DisassemblyEquipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pin-off tool capableof making a vapo

Seite 8 - Operation

16 Room Air ConditionerSchematic DiagramSchematic DiagramCircuit Diagram MODEL : TOUCH & REMOTE CONTROL TYPE MODELLOCATIONNO.12345678Q'TY PE

Seite 9 - 9 Room Air Conditioner

17 Room Air ConditionerElectronic Control DeviceSchematic Diagram

Seite 10 - Disassembly

Service Manual 18Components Location(For Main P.W.B ASM)Schematic Diagram

Seite 11 - Air Handling Parts

19 Room Air ConditionerTroubleshooting Guide Troubleshooting GuidePiping SystemFigure 38 is a brief description of the important components and their

Seite 12 - Electrical Parts

2 Room Air ConditionerAir Conditioner Service ManualTABLE OF CONTENTSSafety Precautions...

Seite 13 - Refrigerating Cycle

Service Manual 20Troubleshooting GuideTroubleshooting GuideIn general, possible trouble is classified in two kinds.The one is called Starting Failure

Seite 14 - 3. CAPILLARY TUBE

21 Room Air ConditionerTroubleshooting GuideFails to StartImproper thermistorsettingLoose terminalconnectionImproper wiringCheck of power source.Drop

Seite 15 - Figure 30A-Pulling Vacuum

Service Manual 22Troubleshooting Guide MODEL : BG8000ER, WG8000RY4, WG1000RY4ELECTRIC PARTS TROUBLESHOOTING GUIDE:Possible Trouble 1• The unit does n

Seite 16 - Schematic Diagram

23 Room Air ConditionerTroubleshooting GuideIs Temp.setting set lower than Room Temp.-0.5°C?Is the voltage No.10of IC01M 0V?• Exchange IC01M.• Set the

Seite 17 - Electronic Control Device

Service Manual 24Troubleshooting GuideIs the voltage of Batteryabout over 2.3V?•Exchange Receiver Ass'y.Is the connection of CN-DISP1 all right?I

Seite 18 - Service Manual 18

25 Room Air ConditionerTroubleshooting GuideROOM AIR CONDITIONER VOLTAGE LIMITSNAME PLATE RATING MINIMUM MAXIMUM115V ± 10% 103.5V 126.5VCOMPLAINT CAUS

Seite 19 - Troubleshooting Guide

Service Manual 26Troubleshooting GuideCOMPLAINT CAUSE REMEDYFan motor noise. Fan If cracked, out of balance, or partially missing,replace it.Blower If

Seite 20

27 Room Air ConditionerCOMPLAINT CAUSE REMEDYCompressor cycles on Voltage Check the voltage. See the limits on theoverload. preceding page. If voltage

Seite 21 - 21 Room Air Conditioner

Service Manual28Exploded ViewExploded Vie w24995023831023720055403035901155211355210235211A352113135500W0CZZ567480264100W5210E-2W5210E-1268711-1268711

Seite 22 - Exchange D02D~D05D

29 Room Air ConditionerReplacement Parts listLocNo CP10E10 CP12E10 DESCRIPTION REMARK130410 67302929 67302929 Base Assy Single R349001 67303508 6730

Seite 23 - Possible Trouble 4

Service Manual 3Safety Precautions Safety PrecautionsTo prevent injury to the user or other people and property damage, the following instructionsmu

Seite 24 - Possible Trouble 6

CP10 CP12 SVC PARTS 2008(07/08) Post Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540 • (210) 357-4400 • FAX (210

Seite 25 - 25 Room Air Conditioner

4 Room Air ConditionerSafety Precautions Plug in the power plugproperly.• Otherwise, it will causeelectric shock or fire.Do not operate or stop theu

Seite 26 - Service Manual 26

Service Manual 5Safety Precautions CAUTION•• ••• If water enters the product, turn off the thepower switch of the main body of appliance.Contact ser

Seite 27 - 27 Room Air Conditioner

6 Room Air ConditionerDimensionsDimensionsOutside DimensionsThis symbol alerts you to the risk of electric shock. This symbol alerts you to hazards th

Seite 28 - Exploded Vie w

Service Manual SpecficationsProduct SpecificationsSer 7Product SpecificationsSerProduct SpecificationsProduct SpecificationsPOWER SUPPLYCOOLING CAPACI

Seite 29 - Replacement Parts list

OperationLocation and Function of Controls • DESIGNED FOR COOLING ONLY • POWERFUL AND INCREDIBLE COOLING• TOP-DOWN CHASSIS FOR THE SIMPLE INSTALLAT

Seite 30 -

AirP urifierPowerTempModeTimerAS wingFan S peed124350FPowerModeTimer0n/0ffFan SpeedTemp CoolMoney Saver®Fan OnlyDryhrAutoSwing123457AutoSwing666. AUT

Kommentare zu diesen Handbüchern

Keine Kommentare